Introducing The NEW Spectra PHORAD® Photometer SC-850 replacing model SC-820

Control the Lighting Condition Under Which Radiographs and Images are Viewed and Interpreted

Widest Dynamic Range is from one hundred million to one cd/m2 and nits; the low luminance level is down to 0.01 cd/m2 and nits and the high luminance measurement is up to 2,000,000 cd/m2 and nits. Measure really black and bright white images accurately, for example, calibrating displays and projectors.
Also, to optimize image contrast, it also measures the viewing room’s ambient background illumination falling on the viewer’s surface as set forth in the new standards.
The New Spectra PHORAD Photometer is exclusively designed for radiologists and Radiographers for NDT/QA application and is well known for its precision, accuracy, and repeatability.
This New Spectra PHORAD display Photometer model SC-850 is the greatest improvement over the previous model PHORAD SC-820.
The new Spectra PHORAD Display Photometer has the widest dynamic range ever in a hand-held photometer in the market it measures one hundred million to one cd/m2 and nits (100,000,000 to 0.01 Nits).

Spectra PHORAD Photometers are essential for quality assurance of medical imaging at Diagnostic Imaging departments in hospitals and clinics. PHORAD is a very easy-to-use and cost-effective photometer in the industry.

This innovative, hand-held radiographic optical instrument is a completely portable, battery-powered auto-ranging photometer designed specifically to measure the light intensity of medical diagnostic imaging displays, film viewing boxes, image monitors, collimator light field, etc.  Photometer reads directly in candelas pe meter squared (cd/m2) and nits or foot lamberts as set forth in the new standards outlined in the  Standard Practice for Radiographic Examination (ASTM E-1742-08).

Also to optimize image contrast, it also measures the viewing room ambient background illumination falling on the viewer surface as set forth in the new standards.

DIAGNOSTIC IMAGING BACKGROUND

Diagnostic Imaging (Radiology) Accuracy and reliability of diagnosis in hospitals and doctors’ clinics greatly depend upon the conditions under which radiographs and images are viewed. These conditions include the luminance levels in candelas per meter squared (cd/m2) of the display devices (viewing boxes, image workstation monitors, image intensifier monitors) as well as the ambient room illumination (the amount of light falling on the viewing surfaces) in lux.

In an effort to reduce the rate of misdiagnosis (estimated to be as high as 30% by a number of research studies), the Federal Drug Administration, American College of Radiology (ACR), the American Cancer Society and the European community of radiologists have all adopted guidelines and standards for viewing lighting levels.

In order to improve the quality of image interpretation and to reduce the chance of misdiagnosis. Spectra Cine is introducing this New Spectra PhoRad  Photometer and it could easily provide radiology departments with a hand-held photometer that measures both display device luminance and ambient light (illuminance).

Spectra PhoRad Photometer measures light output of illuminator to ensure that user is in compliance with ASTM E-1742-08 and ACR-recommended light levels. Readings are in nits or candelas per meter squared (cd/m2) or foot Lamberts (fl). A second Cosine Corrected Diffuser to measure the Ambient light in lux (lx) or foot-candles (fc). This instrument is essential for quality assurance of medical imaging at Diagnostic Imaging departments in hospitals and clinics.

Preliminary Specifications:

The New Spectra PHORAD display measurement photometer model SC-850 is an advanced device designed to measure light intensity with high accuracy for measuring display. The hardware includes a powerful microprocessor, a 2.8-inch color TFT LCD display, and signal conditioning circuitry for greater sensitivity and accuracy. The display is equipped with touch screen and controlled backlighting, making it easy to use and read in any lighting conditions. The battery power management system ensures that the meter can be used for extended periods without replacing the battery or needing to recharge.
The firmware for the microprocessor was developed using a popular development framework and a graphics library for managing the touch display. This firmware handles hardware initialization and control, auto ranging, display, storage, energy saving, settings, calibration, and diagnostics. It is designed to provide accurate and reliable light measurement readings.
The Spectra Cine Professional V Light Meter architecture is based on its predecessor the Spectra PHORAD photometer model SC-820 Meter technology, which was awarded multiple Engineering awards.
It features a transimpedance and multiple-range linear circuit, making it the widest dynamic range circuit available in a handheld meter design. The meter is designed to measure from one hundred million to one or 0.01 to 1,076,400 lux, making it suitable for the widest range of applications.
The Spectra Phorad Photometer is ambient and luminance light measurement with luminance probe, making it suitable for use in a variety of settings. It measures ambient light with cosine corrected diffuser in Lux and foot candles. This makes it easy to measure light intensity accurately and reliably.
The meter can store up to ten different measurements. This memory feature can recall RCL and delete memorized readings, and foot-candles and lux combinations in mem0 to mem9 addresses. The stored readings can be recalled with a simple press of the RCL switch, and a long press on the STR switch which deletes the stored reading.
The Spectra Phorad Photometer also includes a touch menu on the screen, which takes you to a Menu screen where you can select Edit, Hardware Settings, and Product Information. This feature makes it easy to customize the meter to suit your specific needs.
Flexible power supply: The device can be powered using 3 x AA 1.5 volts long-lasting lithium batteries or 3 x AA Nicad rechargeable batteries. or Spectra Power Bank which can be purchased separately. It can be connected via the meter’s USB C port and should be able to continuously operate the meter for several days. To extend the life of the batteries the backlight display should be set at 50% brightness for optimum brightness and power conservation. The backlight display brightness can be adjusted from 5% to 100%.
In summary, the New Spectra Phorad photometer is an advanced device designed to measure light measurement accurately and reliably. It features a range of advanced technologies and functions that make it suitable for use in a wide range of demanding applications.
Accessories supplied: The Spectra meter comes with Luminance probe for surface luminance measurement in cd/m2 and nits or foot lamberts, cosine corrected Photo Disc (for key or directional light), Meter Carrying case, Neck-strap, 3 x AA batteries lithium, Quick reference chart (brief instructional manual), and a warranty registration form to be filed online at www.myspectra.com.

Preliminary Specifications:

⦁ Hardware: The device features a powerful microprocessor, a 2.8-inch TFT color touch display, optical sensor circuitry, and battery management.
⦁ Firmware: The firmware for the microprocessor was developed using a powerful development framework and a graphics library that manages the touch display, auto ranging, display, storage, energy-saving, settings, calibration, and diagnostics.
⦁ Measuring range: The device has a wide dynamic range from 0.01 to 1,076,400 lux and from 0.01 to 100,000-foot candles.
⦁ Measurement types: The device offers two types of measurements: Ambient light (incident) and reflected or luminance display measurement in cd/m2 and nits and foot lamberts (with a 10-degree measuring field probe).
⦁ Accuracy: The device is highly accurate.
⦁ Measuring units: The device displays measurements in lux/fc.
 Memory: The device can store up to 10 different measurements, which can be recalled using the RCL switch.
⦁ Memory recall of all measurements and calculations: By pressing the recall (RCL) switch, the first stored reading (mem0) can be displayed, and subsequent readings can be recalled up to mem9. The recalled readings may have different lux or footcandles and luminance mode cd/m2, nits or foot lamberts.
⦁ Memory erasure: Long pressing the STR switch deletes the stored readings. All stored readings can be erased by pressing and holding the STR switch.
 Display: The device features a 2.8-inch TFT color display with 240×320 pixels. The backlight display brightness can be adjusted from 5% to 100%.
⦁ Display touch screen: The device has several screens including Illuminance, Luminance Menu, and Product information.
⦁ Menu options: The device offers menu options to
⦁ Flexible power supply: The device can be powered using 3 x AA 1.5 volts long-lasting lithium batteries or 3 x AA Nicad rechargeable batteries. The Spectra Power Bank is optional, which can be connected via the meter’s USB C port and should be able to continuously operate the meter for several days. To extend the life of the batteries, the backlight display should be set at 50% brightness for optimum brightness and power conservation.
⦁ Power/ ON Switch: Turns the Power ON (Power switch is on the left side of the meter). The display will turn on and display previous settings, and now you may want to measure take a reading by pressing Read/On-measure switch (measure switch is on the right side of the meter). After taking a reading, the readings will be held on the display for 60 seconds or until the Power switch is turned off to conserve power. The meter will automatically turn off after 60 seconds of non-use.
⦁ Accessories supplied: The Spectra PHORAD display Photometer comes with calibrated Luminance probe for measuring surface luminance of display in cd/m2 and nits or foot lambert ; and cosine corrected Photo Disc for ambient light to measure in Lux and foot candles, Carrying case, Neck-strap, 3 x AA batteries, Quick reference chart (brief instructional manual), and a warranty registration form to be filed online at  www.myspectra.com.

Preliminary Specifications

SPECTRA PHORAD DISPLAY PHOTOMETER
LUMINANCE & AMBIENT MEASUREMENT
MODEL NO-SC-850

⦁ TYPE: Spectra PhoRad Photometer System is a completely portable hand-held, battery powered auto ranging photometer for measuring luminance intensity in candelas per meter squared (cd/m2) with the Luminance Probe and ambient light in lux (lx) with the cosine corrected Photodisc.

⦁ LIGHT SENSOR: Ultra-stable silicon photodiode, together with computer selected glass filters to match the spectral response of the human eye (the CIE 1931 photopic response function) V (λ) filter.

⦁ MEASURING PRINCIPLE: Contact measurement with the Luminance Probe placed directly on the surface to be measured.
⦁ MEASURING CAPABILITY: Measures luminance  level in candelas per meter squared (cd/m2) and Nits or Foot Lamberts and ambient light in lux or Foot candles
LUMINANCE RANGE: 0.01 – 1,000,000 cd/m2 (Nits)
ILLUMIANANCE RANGE: Ambient range 1 – 100,000, Lux (lx)

⦁ COSINE RESPONSE: Cosine response of the meter with Cosine Corrected Photodisc is 2%

⦁ RESOLUTION: 1 to 999  in 1 cd/m2 / Lux  increments; 1,000 to 99,990 in 10  increments

⦁ ACCURACY: Incandescent light source (CIE Illuminant A) ±2.5% of the measured value., Additional error when measuring non-blackbody sources ±3%. ⦁ REPEATABILITY: ±0.2%

⦁ CALIBRATION: Calibration is traceable to the National Institute of Standard Technology (NIST), Washington D.C. Certified for one year.⦁ LAMP: Electroluminescent lamp for backlit display⦁ POWER SOURCE: One 6 volt battery #A544, PX28L, PX28⦁ DIMENSIONS: 5 ½”;” x 2 ½” x 2″⦁ WEIGHT: Approximately 8 ounces⦁ WARRANTY: One year limited warranty.⦁SPECTRA PHORADSYSTEM IS SUPPLIED WITH:

Phorad Photometer, luminance probe (luminance measurement), photodisc- cosine corrected diffuser (ambient measurement), attractive, sturdy foam-lined protective carrying case with space for accessories, Instruction Manual, NIST Traceable Calibration (certified for one year) and Battery

⦁ MANUFACTURED IN UNITED STATES OF AMERICA
Complies with Standard Practice for Radiographic Examination ASTM E-1742-08 Specifications.
* OPERATING TEMPERATURE RANGE: 32˚F TO 130˚F (0˚C TO 55˚C).
* SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

Preliminary Specifications:

Introducing The NEW Spectra PHORAD® Photometer SC-850

We are proud to introduce the latest addition to our product line, the Spectra PHORAD® Display Photometer SC-850. This new model replaces the previous SC-820 and offers significant improvements in performance and features. Designed specifically for radiologists and radiographers in the field of Non-Destructive Testing (NDT) and quality assurance (QA) applications, the SC-850 is renowned for its precision, accuracy, and repeatability.

Control the Lighting Condition Under Which Radiographs and Images are Viewed and Interpreted

The Spectra PHORAD® Display Photometer SC-850 allows you to have complete control over the lighting conditions under which radiographs and images are viewed and interpreted. It provides the widest dynamic range ever seen in a hand-held photometer, allowing you to measure luminance levels ranging from as low as 0.01 cd/m2 and nits to as high as 2,000,000 cd/m2 and nits. This wide range ensures accurate measurement of both really black images and bright white images, making it ideal for calibrating displays and projectors.

Optimizing Image Contrast and Meeting New Standards

In addition to its impressive dynamic range, the SC-850 also measures the viewing room’s ambient background illumination falling on the viewer’s surface, in accordance with the new standards. This feature helps optimize image contrast, leading to improved image interpretation and reducing the chance of misdiagnosis. The instrument complies with the guidelines and standards set by the Federal Drug Administration, American College of Radiology (ACR), the American Cancer Society, and the European community of radiologists.

Key Features and Benefits
Widest dynamic range in a hand-held photometer: Measures from 0.01 cd/m2 and nits to 2,000,000 cd/m2 and nits, allowing accurate measurement of a wide range of luminance levels.
Precision, accuracy, and repeatability: The SC-850 is designed to deliver precise and reliable measurements, ensuring confidence in the quality of your imaging results.
Easy to use and cost-effective: Spectra PHORAD® Photometers are known for their user-friendly interface and affordability, making them an excellent choice for quality assurance in medical imaging departments.
Applications and Versatility

The Spectra PHORAD® Display Photometer SC-850 is an innovative, portable, and battery-powered auto-ranging photometer that can be used for various applications. It is specifically designed to measure light intensity in medical diagnostic imaging displays, film viewing boxes, image monitors, and collimator light fields, among others. The photometer provides direct readings in candelas per meter squared (cd/m2) and nits, in accordance with the standards outlined in the ASTM E-1742-08 Standard Practice for Radiographic Examination.

Ensure Compliance and Improve Diagnosis Accuracy

By measuring both display device luminance and ambient light (illuminance), the SC-850 enables radiology departments to meet the recommended light levels set by organizations such as the ACR. This ensures compliance with standards and helps improve the accuracy and reliability of diagnosis, ultimately reducing the rate of misdiagnosis.

We believe that the Spectra PHORAD® Display Photometer SC-850 is a groundbreaking advancement in the field of radiographic optical instruments. Its exceptional performance, ease of use, and affordability make it an essential tool for quality assurance in diagnostic imaging departments in hospitals and clinics.

Upgrade to the Spectra PHORAD® Display Photometer SC-850 today and experience the unparalleled precision and versatility it offers.

Specifications:

Hardware:
⦁ Microprocessor: Powerful microprocessor for efficient operation.
⦁ Display: 2.8-inch TFT color touch display for easy navigation and measurement visualization.
⦁ Optical Sensor Circuitry: Advanced circuitry for accurate light intensity measurement.
⦁ Battery Management: Efficient management system for battery usage.

Firmware:
⦁ Development Framework: Powerful development framework for firmware implementation.
⦁ Graphics Library: Graphics library that manages the touch display, auto-ranging, display settings, storage, energy-saving, calibration, and diagnostics.

Measuring Range:
⦁ Dynamic Range: Wide measuring range from 0.01 to 1,076,400 lux and 0.01 to 100,000 foot candles.

Measurement Types:
⦁ Ambient Light: Measurement of incident light.
⦁ Reflected/Luminance Display: Measurement of luminance display in cd/m2, nits, and foot lamberts using a 10-degree measuring field probe.

Accuracy:
⦁ High accuracy for precise measurement results.

Measuring Units:
⦁ Lux/fc: Measurements displayed in lux (lux) and foot candles (fc).

Memory:
⦁ Storage Capacity: Can store up to 10 different measurements.
⦁ Memory Recall: Recall stored readings using the RCL switch.
⦁ Memory Erasure: Erase stored readings by long-pressing the STR switch.
Display:
⦁ TFT Color Display: 2.8-inch TFT color display with 240×320 pixels.
⦁ Backlight Adjustability: Adjust the backlight display brightness from 5% to 100%.

Display Touch Screen:
⦁ Interactive touch screen for easy navigation and selection of various screens.

Menu Options:
⦁ Offers menu options for customization and settings.

Flexible Power Supply:
⦁ Battery Options: Can be powered by 3 x AA 1.5V long-lasting lithium batteries or 3 x AA Nicad rechargeable batteries.
⦁ Optional Spectra Power Bank: Can be connected via the meter’s USB C port for extended operation.

Power/ON Switch:
⦁ Power ON: Turn the meter ON using the power switch.
⦁ Read/On-Measure Switch: Take readings by pressing the measure switch.
⦁ Auto Power Off: Meter automatically turns off after 60 seconds of non-use.

Accessories Supplied:
⦁ Calibrated Luminance Probe: Included for measuring surface luminance in cd/m2, nits, or foot lamberts.
⦁ Cosine Corrected Photo Disc: Included for ambient light measurement in lux and foot candles.
⦁ Carrying Case, Neck-Strap, 3 x AA Batteries: Provided for convenience.
⦁ Quick Reference Chart: Brief instructional manual.
⦁ Warranty Registration Form: Online registration at ⦁ www.myspectra.com.

Specifications are subject to change without notice, ensuring the most up-to-date features and improvements.

Specifications:
⦁ Hardware: The device features a powerful microprocessor, a 2.8-inch TFT color touch display, optical sensor circuitry, and battery management.
⦁ Firmware: The firmware for the microprocessor was developed using a powerful development framework and a graphics library that manages the touch display, auto ranging, display, storage, energy-saving, settings, calibration, and diagnostics.
⦁ Measuring range: The device has a wide dynamic range from 0.01 to 1,076,400 lux and from 0.01 to 100,000-foot candles.
⦁ Measurement types: The device offers two types of measurements: Ambient light (incident) and reflected or luminance display measurement in cd/m2 and nits and foot lamberts (with a 10-degree measuring field probe).
⦁ Accuracy: The device is highly accurate.
⦁ Measuring units: The device displays measurements in lux/fc.
⦁ Memory: The device can store up to 10 different measurements, which can be recalled using the RCL switch.
⦁ Memory recall of all measurements and calculations: By pressing the recall (RCL) switch, the first stored reading (mem0) can be displayed, and subsequent readings can be recalled up to mem9. The recalled readings may have different lux or footcandles and luminance mode cd/m2, nits or foot lamberts
⦁ Memory erasure: Long pressing the STR switch deletes the stored readings. All stored readings can be erased by pressing and holding the STR switch.
⦁ Display: The device features a 2.8-inch TFT color display with 240×320 pixels. The backlight display brightness can be adjusted from 5% to 100%.
⦁ Display touch screen: The device has several screens including Illuminance, Luminance Menu, and Product information.
⦁ Menu options: The device offers menu options to
⦁ Flexible power supply: The device can be powered using 3 x AA 1.5 volts long-lasting lithium batteries or 3 x AA Nicad rechargeable batteries. The Spectra Power Bank is optional, which can be connected via the meter’s USB C port and should be able to continuously operate the meter for several days. To extend the life of the batteries, the backlight display should be set at 50% brightness for optimum brightness and power conservation.
⦁ Power/ ON Switch: Turns the Power ON (Power switch is on the left side of the meter). The display will turn on and display previous settings, and now you may want to measure take a reading by pressing Read/On-measure switch (measure switch is on the right side of the meter). After taking a reading, the readings will be held on the display for 60 seconds or until the Power switch is turned off to conserve power. The meter will automatically turn off after 60 seconds of non-use.
⦁ Accessories supplied: The Spectra PHORAD display Photometer comes with calibrated Luminance probe for measuring surface luminance of display in cd/m2 and nits or foot lambert ; and cosine corrected Photo Disc for ambient light to measure in Lux and foot candles, Carrying case, Neck-strap, 3 x AA batteries, Quick reference chart (brief instructional manual), and a warranty registration form to be filed online at ⦁ www.myspectra.com.

Get In Touch With Us!

Phone

(818) 954-9222

Email

naszaidi@gmail.com

Address

Spectra Cine, Inc. 3607 W. Magnolia Blvd. Burbank, CA 91505, U.S.A.